High-performance fire-rated riser door panels with acoustic, smoke and airtight performance, supporting safe M&E access in premium residential corridors.
London Square Nine Elms is a premium residential scheme within the Nine Elms regeneration area. Across Plots E, F & G, the project required riser and wall access panels that would provide safe, secure access for building services while meeting stringent performance requirements for modern residential corridors.
The project demanded riser access panels with tested fire performance suitable for high-rise residential environments, acoustic comfort for corridors and shared spaces, smoke and airtight performance alongside fire rating, and a flush aesthetic that remained discreet within high-end finishes.
Rapid Fit hinge system with 120-minute fire rating, 33dB acoustic performance, smoke tested and airtight Class 2. 3-point locking with beaded frame.
Double door wall access panels with 2-hour fire rating for larger riser openings. 3-point locking, smoke tested, powder coated and primed for on-site decoration.
Multi-door riser door units with three or more panels for the widest riser and service shaft openings, maintaining the same fire, acoustic, and smoke performance as single and double configurations.
The Rapid Fit hinge system supported efficient on-site fitting, helping maintain programme flow while delivering a flush, discreet finish suitable for premium residential environments.
Metal-faced panels with beaded frames, powder coated and primed for on-site decoration. Designed to sit flush and remain discreet within high-end residential interiors.
Rapid Access delivered high-performance riser door panels that met the strict compliance and aesthetic requirements of a premium residential development.
Fire-rated riser access aligned with modern residential compliance needs, with panels tested delivering up to 2-hour fire performance.
Acoustic performance to support quieter shared spaces, with panels tested to 33dB (BS EN ISO 10140-2:2010) to protect resident comfort in corridors and communal areas.
Smoke and airtight performance added protection and control, with panels smoke tested to BS EN 1634-3:2004 and airtight rated to BS EN 1026:2016 for enhanced safety.
Secure 3-point locking for riser safety and access control, ensuring authorised access to M&E services while maintaining security throughout the building.
A clean, flush corridor finish that complements high-end interiors, with powder coated and primed panels designed for seamless on-site decoration.
Independently tested to the highest industry standards for fire safety, quality management, and construction.
ISO 9001:2015, Quality Management
ISO 14001:2015, Environmental
ISO 45001:2018, Health & Safety
UKAS Accredited