Fire Rated Access Panels

Tested Protection. No Compromise.

Every fire rated access panel we manufacture is tested and trusted across UK projects where compliance isn't optional. Manufactured in the UK, tested up to 120 minutes, and delivered in days — not weeks.

0
Max Fire Rating
0
Standard Lead Time
0
30 / 60 / 90 / 120 min
0
UK Manufactured

In modern construction, fire integrity is everything. A non-compliant fire rated access panel can ruin a sign-off and risk lives. We manufacture fire rated access panels that preserve compartmentation, maintain design standards, and keep your project moving fast. Every panel leaving our UK facility has been independently tested and verified to meet BS 476 Part 22, BS EN 1634-1:2014+A1:2018 and BS EN 1364-2:2018 standards.

Last updated: March 2026 · Reviewed by Rapid Access Technical Team

Fire rated access panel showing intumescent seal and steel frame

Independently Tested

All panels are independently tested under UK and European standards to confirm fire resistance. Each unit is supplied with test documentation, installation guidance, and compliance data ready for submission to Building Control.

Independently Tested

Tested to BS 476 Part 22, BS EN 1634-1:2014+A1:2018 and BS EN 1364-2:2018 by UKAS-accredited laboratories with full certification supplied.

Ratings Up to 120 Minutes

Available in 30, 60, 90 and 120 minute fire ratings for both integrity and insulation performance.

Walls & Ceilings

Suitable for both wall and ceiling applications with specific fixing methods for each orientation.

Multiple Face Types

Plasterboard-faced or metal-faced options with beaded or picture frame profiles to suit your wall finish.

Fire Rating & Testing
Performance

Our testing covers integrity, insulation, and stability, ensuring performance in both wall and ceiling applications.

SpecificationValue
Fire StandardBS 476 Part 22, BS EN 1634-1:2014+A1:2018 & BS EN 1364-2:2018
Fire Rating30 / 60 / 90 / 120 min
ApplicationWalls & Ceilings
Face TypesMetal / Plasterboard / Tile
Frame TypesBeaded / Picture Frame
Lead Time3–5 working days
ManufactureUK (Nuneaton)

Advantages of Fire Rated
Access Panels

Fire rated access panels protect compartmentation, ensure compliance, and deliver fast — with no compromise on quality or certification.

Maintains Fire Compartmentation

Protects walls and ceilings by ensuring service penetrations do not compromise fire integrity.

Compliant with UK Standards

Tested to BS 476 Part 22, BS EN 1634-1:2014+A1:2018 and BS EN 1364-2:2018 for complete building regulation compliance.

Suitable for Walls and Ceilings

Available in both orientations with tested fire ratings from 30 to 120 minutes.

Seamless Integration

Choose plasterboard-faced for a paintable concealed finish or metal-faced for durability.

Fast UK Delivery

Standard and custom fire-rated panels available in as little as 3–5 working days.

UK Manufacturer Direct

No middlemen, no imports. Full control of production, quality and delivery from our Nuneaton facility.

Not sure which access
panel you need?

Answer a few questions about your project and we'll recommend the right panel type, face finish and performance rating for your specification.

1
Tell us about the project Building type, location & environment
2
Select your requirements Fire rating, security, acoustic needs
3
Get your recommendation Panel type, finish & full spec sheet
Help Me Specify

Where Fire Rated Access
Panels Are Used

Our fire rated panels are trusted and specified across a wide range of construction sectors and building types.

Fire rated access panels in service risers and plant rooms

Service Risers & Plant Rooms

Fire-protected access to concealed services in vertical risers and mechanical plant rooms.

Fire rated access panels in hospital corridors and escape routes

Corridors & Escape Routes

Maintaining compartmentation along fire-protected corridors and means of escape.

Fire rated access panels in hospitals and healthcare facilities

Hospitals & Healthcare

Tested panels for wards, operating theatres, and clinical environments requiring strict fire compliance.

Fire rated access panels in schools, airports, and public buildings

Schools & Public Buildings

Fire rated access for classrooms, halls, airports, and multi-storey public buildings.

Fire rated access panels in hotels and mixed-use developments

Hotels & Mixed-Use

Commercial offices, hotels, and mixed-use developments with stringent fire strategy requirements.

Fire rated access panels in residential towers and apartment blocks

Residential Towers

Apartment blocks and residential towers requiring Building Regulations Part B compliance.

From Enquiry to Delivery

A streamlined process designed for speed and precision, from initial consultation to site delivery.

1

Consultation

Discuss your project requirements, including sizes, ratings, quantities, and finishes with our technical team.

2

Specification

We provide a detailed specification sheet, CAD drawings, and a competitive quotation within 24 hours.

3

Manufacture

Panels are CNC-cut, formed, assembled, and finished in our UK facility with full quality traceability.

4

Delivery

Nationwide delivery on palletised, shrink-wrapped consignments. Standard lead time 3-5 working days.

Fire Rated Access Panel
FAQ

Everything you need to know about specifying, ordering and installing fire rated access panels.

Our fire rated access panels are available in 30, 60, 90 and 120 minute integrity ratings, independently tested to BS 476 Part 22, BS EN 1634-1:2014+A1:2018 and BS EN 1364-2:2018. The required rating depends on the fire strategy for your building and the compartmentation requirements of the wall or ceiling being penetrated.
All fire rated access panels are independently tested to BS 476 Part 22 (fire resistance), BS EN 1634-1:2014+A1:2018 (fire resistance of door and shutter assemblies) and BS EN 1364-2:2018 (non-loadbearing elements). Testing is carried out by UKAS-accredited laboratories and covers integrity, insulation, and stability. Test reports are supplied with every order.
Yes. Our fire rated access panels are tested for both wall and ceiling applications. Ceiling installations use specific fixing methods to maintain fire performance, and installation guidance is included with every panel.
Fire rated access panels are available in metal faced, plasterboard faced, and tile faced options. Metal faced panels offer durability and a clean finish. Plasterboard faced panels can be skimmed and painted to match the surrounding surface. Tile faced panels accept tiles for a concealed finish in tiled environments.
Standard fire rated access panels ship within 3–5 working days. Bespoke and made-to-measure panels are typically ready in 3-5 working days. We manufacture in the UK so there are no import delays.
Yes. We manufacture bespoke fire rated access panels to your exact dimensions. There is no minimum or maximum size restriction. Custom panels maintain the same fire performance and are supplied with the same certification and documentation as standard sizes.

Quality You Can Trust

Independently tested to the highest industry standards for fire safety, quality management, and construction.

Need help specifying? Chat with Athena from our technical team.
ISO 9001:2015 Quality Management ISO 9001:2015, Quality Management
ISO 14001:2015 Environmental Management ISO 14001:2015, Environmental
ISO 45001:2018 Health & Safety ISO 45001:2018, Health & Safety
UKAS Accredited Management System UKAS Accredited
View All